PRODUCTS:
Test, Measuring & Control Instruments |
|
|
|
Wrist
Strap Tester
|

|
Specifications |
Pass
Band
|
0.75
Megohms to 10 Megohms. |
Indications
|
Pass
- Green LED
Fail - RED LED
Audible Alarm for Fail mode. |
Actuation |
By
gently pressing metal sensor plate. |
Accuracy
|
+10%. |
Power
supply |
9
V volts battery |
|
Dual
Footwear Tester Z104 & Foot plate |

|
Specifications |
Pass
Range
|
0.75
meg ohms to 35.0 meg ohm. |
Indications
|
Pass
- GREEN LED
Fail (low) - RED LED
Fail (high) - RED LED
Audible Alarm for Fail mode. |
Actuation
|
By
gently pressing metal sensor plate. |
Accuracy
|
+
10% |
Power
supply
|
9
V DC battery |
Low
Battery |
:
Orange - Warning less than 7 volts. |
|
100v
Surface Resistivity Meter SRM-02 |

|
Specifications |
Measurement
Range
|
<10^3 to >10^12
Ohms
(or) Ohms/sq |
Measurement
Accuracy
|
Half
decade |
Resolution
|
One
decade |
Test
Voltage
|
100V |
Indication
|
Different
Color LED’s
|
Test
actuation
|
Press
To Read Switch |
Power
supply
|
9
Volt Battery |
Low
battery threshold
|
Test
Voltage across probes
80V (+/-1V) |
Low
Battery Indication
|
Flashes
by Red 10^13 LED |
Dimensions
|
135
x 70 x 30mm |
Weight
|
200
Gms |
Calibration
|
Recommended
every 12 months |
Warranty
|
12
Months |
Accessories
|
Surface
to Ground cord & Carry Case |
Optional |
Testing & Measuring Probes |
|
Combo
Tester Z134 & Stand
|

|
Specifications |
Pass Range
|
Wrist
strap 0.75 to 10.0 meg ohm
Footwear 0.75 to 35.0 meg ohm |
Actuation
|
By
gently pressing TEST button |
Accuracy
|
+
10% |
Power
supply
|
Included |
Calibration
|
Recommended
every 12 months |
Traceability |
To
national standards |
|
Surface
Resistivity MeterZ203
|

|
Specifications |
Measurement
Range |
10^3
to 10^13 ohms/sq |
Measurement
accuracy
|
Half
Decade
|
Resolution
|
One
Decade
|
Excitation
voltage
|
9 V
|
Indication
|
Visual
by LEDs
|
Test
actuation
|
Press
to ON Switch |
Power
supply |
9
Volt DC battery |
|
Static
MeterZ205
|

|
|
Workstation
MoniterZE107
|
 |
|
Static
Discharge Stand
|
 |
|
Static
Eliminator Z207
|
 |
Specifications |
Air
Flow |
1.8
cu m/min |
Noise
level
|
45
dbA (at 1m) |
Supply
|
230V
AC 50Hz 20 Watts |
Ionization
voltage
|
6-8 KV |
Ion
balance
|
under
-/+ 50 V |
Construction
|
Powder coated MS cabinet |
Dimensions
in mm
|
170
x 90 x 200 |
Weight
|
2.75 kgs
|
Warranty |
One
year |
|
IonizerGun-Metal
|
 |
|
IonizerOverhead
3fan Z209
|
 |
Specifications |
Measurement
Range |
10^3
to 10^13 ohms/sq |
Measurement
accuracy
|
Half
Decade |
Resolution
|
One
Decade |
Excitation
voltage
|
9 V |
Indication
|
Visual
by LEDs |
Test
actuation
|
Press
to ON Switch
|
Power
supply |
9
Volt DC battery |
|
Electrostatic
AlarmZ201
|
 |
|
Human
Body Voltage Checker
|
 |
|
|
|
 |
|